AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (880.3 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Microwave Signal Replicator Design for Testing of the Multi-Channel Transcranial Magnetic Stimulator

Qiuju Chen1,2Kai Zhang1( )Jian Pang1Shancai Zhang1Guangyao Feng1Congfeng Wu1Wei Li3
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
Laboratory for Big Data and Decision, Hefei 230027, China
Advanced Manufacturing Engineering College, Hefei University, Hefei 230601, China
Show Author Information

Abstract

The multi-channel transcranial magnetic stimulator is commonly used for rehabilitation treatment of ischemic cerebrovascular disease, neurosis, and brain injury diseases in the elderly. And multiple high coherency signals are required as inputs for its test, which are with consistent frequency, adjustable amplitude, equal magnitude, and long-time phase consistency ±1°. But ordinary signal sources have only one output channel, which is far from meeting the test requirements. If the traditional power division is used for the duplication, the phase difference between the channels will be larger than ±1°. If the multi-throw Radio Frequency (RF) switch is used, it will seriously affect the phase consistency of the input signal and increase the distortion of the signal. In order to solve the above problems, the method to extend the output of the microwave signal source has been proposed in the paper by using the integrated transceiver AD9361. The proposed method can realize the duplication of the number of signal channels according to user requirements. Then a signal replicator has been designed by combining AD9361 chip and Field-Programmable Gate Array (FPGA) control module. The experimental platform has been built to test the performance of the designed device. Experimental results show that the duplicated signals are highly consistent with the source signal in the power amplitude and frequency, meanwhile the phase of the duplicated signals are all highly consistent with each other.

References

【1】
【1】
 
 
International Journal of Crowd Science
Pages 83-87

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Chen Q, Zhang K, Pang J, et al. Microwave Signal Replicator Design for Testing of the Multi-Channel Transcranial Magnetic Stimulator. International Journal of Crowd Science, 2024, 8(2): 83-87. https://doi.org/10.26599/IJCS.2024.9100002

1712

Views

174

Downloads

2

Crossref

2

Scopus

Published: 14 May 2024
© The author(s) 2024.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).